Liu jk gotfried on cole cd dougherty.
Titanium mesh orbital floor.
Titanium mesh and cranial bone grafts both seemed to bridge the defects without sagging or changes in shape.
To reconstruct the orbital floor defects there are a lot of reconstruction materials the surgeon must choose one of them.
A study was undertaken to evaluate the safety of magnetic resonance imaging mri of metallic implants used in cranio orbital reconstruction stainless steel wire and titanium and vitallium plates and also to compare the degree of artifact created on computed tomographic ct scanning and mri by each material.
Because of fibrous adhesion around the titanium mesh a proportion of patients experienced persistent diplopia or eyelid retraction beyond two months after the orbital floor repair.
This study was aimed to compare the efficacy of customized patient specific titanium mesh based on 3d printed model with intra operative bending of titanium mesh for reconstructing of orbital floor fracture.
Medpor titan 3d orbital floor.
Those fractures were reconstructed using titanium mesh.
Keywords 3d printed model diplopia enophthalmos orbital fractures surgical mesh titanium.
The defects were reconstructed by titanium mesh in combination with autogenous fascia lata in the orbital floor performed by 1 surgical team.
This is a very rare complication that requires replacing the titanium implant with an implant made from another material or graft.
Thickness color 420 302 1 0 mm 0 2 mm purple 420 303 1 0 mm 0 3 mm teal 420 304 1 0 mm 0 4 mm gold 421 302 1 3 mm 0 2 mm purple 421 303 1 3 mm 0 3 mm teal 421 304 1 3 mm 0 4 mm gold titanium orbital floor plates anatomic small screw dia.
The authors share their experience with 10 patients suffering from orbital trauma causing orbital floor fracture.
Titanium mesh 0 2 mm thick was contoured and fixed to reconstruct the orbital floor and obtain midface projection.
Treatment of orbital fractures involves restoration of lost bone anatomy and orbital volume.
Implants designed using ct scan data to approximate the anatomy of the orbital floor and medial wall.
Among the materials used for this purpose the titanium mesh is widely used due to its effectiveness.
However the one instance where a thin titanium screen was used instead of the thicker stiffer titanium mesh a sagging of the screen and orbital contents inferiorly into the maxillary sinus occurred fig 12.
10 synthes titanium orbital plates technique guide titanium orbital mesh plates screw dia.